logo
Maison
Produits
Au sujet de nous
Visite d'usine
Contrôle de qualité
Contactez-nous
Demande de soumission
Nouvelles
Le blog
TOGETHER HTL LTD
Aperçu Nouvelles

Can I Retrofit a Self-Cleaning Discharge Belt onto an Existing Manual-Clean Magnet? Feasibility, Cost and Payback Explai

TOGETHER HTL LTD est une très bonne entreprise, je suis très disposé à coopérer avec vous, sûr, efficace, professionnel, honnête, heureux ! Merci de me fournir un service et des produits stables. -----EUROPAT

—— EUROPT INDUSTRIEL

Je suis en ligne une discussion en ligne
Société Nouvelles
Can I Retrofit a Self-Cleaning Discharge Belt onto an Existing Manual-Clean Magnet? Feasibility, Cost and Payback Explai
Dernières nouvelles de l'entreprise Can I Retrofit a Self-Cleaning Discharge Belt onto an Existing Manual-Clean Magnet? Feasibility, Cost and Payback Explai

Working Principle — How a Discharge Belt Changes a Manual-Clean Magnet

In a manual-clean magnet, captured tramp iron accumulates directly on the magnet face. Capture strength is high because the iron sits at zero air gap, but the accumulation creates three operating problems: the iron layer grows until it shields the field from the burden below, large pieces can be re-entrained into the material stream when the layer thickens, and removal requires stopping or closely attending to the conveyor.

Adding a discharge belt inserts a controlled, thin air gap — typically 15–25 mm between the magnet face and the belt's inner surface. Iron is still pulled through that gap and pins against the belt's outer surface. The belt moves continuously, so the iron is dragged out of the field's edge zone where its hold weakens, then falls into a discharge chute. The physics mirrors what makes a dedicated magnetic roller work: steady transport through a defined field boundary instead of uncontrolled accumulation.

Three engineering consequences follow, and every retrofit decision must account for them:

1. Capture force drops slightly. The 15–25 mm belt gap reduces effective face field strength by roughly 8–15% compared with bare-face contact. A healthy magnet circuit absorbs this; a weak one does not.

2. The burden-to-magnet distance grows. The kit's pulley diameter and belt section add height, so suspension height must usually be raised 30–80 mm, further reducing field strength at the burden surface. The suspension frame and chain hoist need adjustment range.

3. Iron must travel far enough. The belt must carry iron past the field edge and drop it clear of the conveyor's moving material path — or the magnet will simply recycle the same piece of iron forever, the most common field failure after a poorly planned retrofit.dernières nouvelles de l'entreprise Can I Retrofit a Self-Cleaning Discharge Belt onto an Existing Manual-Clean Magnet? Feasibility, Cost and Payback Explai  0

Case Study — Iron Ore Mine, 1,600 mm Conveyor, Three Magnet Fleet

Customer type: Iron ore open-pit mine, 3-shift operation.

Ore type: Iron ore, high drilling-steel and bucket-tooth contamination.

Operating conditions: 1,600 mm belt at 2.2 m/s, 2,800 t/h, three suspended manual-clean permanent magnets (one per conveyor) aged 9–14 years.

Problem: Each shift lost roughly 2 hours to manual cleaning; the conveyor stopped 4–5 times weekly for iron removal; one primary gyratory suffered two liner-damage events in a year traced to elongated steel released by overloaded magnet faces; pull tests showed 6–11% field fade — inside the retrofit window.

Solution: Factory-engineered retrofit kits on all three magnets: face re-machining on the oldest unit, 1.1 kW gearmotor drives, side discharge chutes feeding shared bins, suspension height re-optimized with new chain hoists. Installation completed over two planned weekend shutdowns, with commissioning capture tests at five belt positions per magnet.

Result: Captured-iron weight per day rose about 2.4× as accumulated-layer shielding disappeared; cleaning labor of roughly 5,900 h/yr across the fleet dropped to near zero; cleaning stoppages fell from ~230 h/yr to zero; crusher damage events went from two per year to zero over the following 12 months; total investment ≈ USD 31,000 for three units against ≈ USD 85,000/yr measured benefit — payback in about 4.4 months, with the oldest magnet scheduled for circuit replacement at the next major overhaul as its fade trended toward the 15% limit.dernières nouvelles de l'entreprise Can I Retrofit a Self-Cleaning Discharge Belt onto an Existing Manual-Clean Magnet? Feasibility, Cost and Payback Explai  1

ontact Us

Contact:serena.meng2022@gmail.com

We warmly welcome customers from around the world to contact us and establish mutually beneficial partnerships.

Temps de bar : 2026-11-27 14:58:27 >> Liste de nouvelles
Coordonnées
TOGETHER HTL LTD

Personne à contacter: Mr. Maple

Téléphone: +86 17778255675

Télécopieur: 86--311-80690567

Envoyez votre demande directement à nous (0 / 3000)